-- RamonaValenzuelaPerez - 2012-06-21

combined_small.png

Proton Detector: Charged Fusion Products Diagnostic

Please note that though Florida International Univeristy (FIU) is collaborating with the Princeton Plasma Physics Laboratory (PPPL) and the Culham Centre for Fusion Energy (CCFE), this TWiki page is maintained by FIU collaborators (FEPP) and the page is hosted by FIU. Please see the CCFE Information section for the address of the Wiki page maintained and hosted by the CCFE.

Proton Detector (PD)

The Proton Detector is a charged fusion products diagnostic created to study MHD instabilities. Most of it was designed, built, and tested at FIU. Testing also took place at the PPPL and CCFE. The PD was then installed in the Mega Amp Spherical Tokamak (MAST) to detect protons and tritons emitted from deuterium-deuterium fusion reactions in the plasma during neutral beam injection. The 4 solid-state detector array was mounted to a MAST probe arm so that the diagnostic could be inserted into the vessel at different radial positions (from the center of the tokamak).

Analogue voltage signals, proportional to the energy deposited by the energetic ions, were continuously digitized at 60MHz during plasma discharges. Proton and triton pulses in these signals were identified to create pulse height spectra and particle rate plots. We are currently in the process of data analysis. We plan to help create proton and trition emission profiles of the plasma during sawtooth, fishbone, and ELM instabilities; this will include comparision to the MAST Neutron Camera and Fission Chamber data.

new_twiki_image_scaled.png

Initial Results

MAST Friday Physics Seminar

  • Friday, September 13th, 2013
  • Culham Centre for Fusion Energy, Culham, England
  • Presentation: MAST_presentation_091313.pdf
  • Presenter: Ramona V Perez
55th Annual Meeting of the Division of Plasma Physics PPPL NSTX-U Physics Meeting
Data Analysis Log

Please click here for DataLog

Data Collection

Dates

  • Parasitic Data collection: August 15th - August 16th & September
  • Dedicated Data collection: August 19th - August 23rd
  • Onsite collaborators (at CCFE)
    • July 22nd - September 13th: Ramona Perez (FIU)
    • August 5th - August 16th: Werner Boeglin (FIU), Adrianna Angulo (FIU), Carlos Lopez (FIU), Omar Leon (FIU), Pierre Avila (FIU)
    • August 12th- August 23rd: Doug Darrow (PPPL)
Dedicated Shots Data Collection
  • Monday August 19th
  • Tuesday August 20th
  • Wednesday August 21st
  • Thursday August 22nd
Parasitic/ Piggybacking Data Collection
  • Thursday August 15th
  • Friday August 16th
  • Friday August 23rd
  • Wednesday September 4th
  • Friday September 6th
  • Monday September 9th
  • Tuesday September 10th
  • Wednesday September 11th
  • Thursday September 12th
Information for sending equipment back to FIU after data collection:

Installation

Dates:

  • FP-001 & FP-005 Planning Meeting: August 5th, August 15th
  • Diagnostic installation: July 22nd - August 12th 2013
  • Proton Detector Completely Installed and Operational: August 15th
PD_INSTALLATION_DETAILS_081613_Ramona.pdf

Electrical Design Review

Final Cable Block Diagram

  • August 2013
  • Draft for Final Cable Block Diagram Drawn by: Ramona Perez
  • Final Cable Block Diagram (below) Drawn by: Andrew Page (CCFE)
  • M11505005.pdf

MAST Electrical Design Review Materials

Date

  • Wednesday June 19th, 2013
  • 9:00 AM FL, 14:00 Culham
Attendees
  • FIU: Adrianna Angulo, Werner Boeglin, Omar Leon, Ramona Perez
  • MAST: Scott Y Allan, Richard Martin, Ken McClements, Paul Stevenson, Nigel Thomas-Davies
  • PPPL: Doug Darrow
EDR Materials Supporting Documents (for reference if needed)

Noise Testing

Dates

  • Onsite noise testing: March 2013
  • Remote noise testing: March - May 2013
Collaborators travelling to MAST
  • Ramona Perez: March 11th - March 24th 2013
  • Werner Boeglin: March 11th - March 15th 2013
  • Doug Darrow: March 11th - March 20th 2013
Instructions to run DAQ Program (if need be) Information for sending equipment back to FIU after remote testing Radiation source Electrical Design
  • cable_block_diagram.pdf
  • All cable lengths used will be the same for the July data collection
  • MAST reciprocating probe cable lengths were simulated for noise testing
Mechanical Design
  • Changes to probe head orientation angles made during noise testing

March 19th, 2013 Noise Testing Group Meeting

Prototype

Installation: January 2013

Comments:

  • Prototype type dimensions fit into RP access cube (reduction in probe head diameter requested for greater ease of installation)
  • Our prototype RP connector may have become distorted during the welding of the connector to the prototype shell (this issue was fixed at CCFE)
  • A dummy RP shaft end was created and sent to FIU to test the fit of the RP connector before bringing the diagnostic for the summer data collection
  • Vacuum vent hole had to be drilled in top of prototype to bake for RP installation (at CCFE)
Machine Drawings:

Mechanical Design Review

Final Mechanical Design

MAST Mechanical Design Review Materials

Date

  • September 9th, 2012
  • Remote from FIU to the CCFE
Presentation Materials Drawings Supporting Documents (for reference if needed)

Preliminary Mechanical Design - MAST

Date

  • June 26th, 2012
Materials

Preliminary Mechanical Design - PPPL

Date

  • June 19th, 2012
Materials

FIU Experimental Plasma Physics (FEPP) Group Information

CCFE Useful Links

Log onto CCFE Citrix network

Citrix errors and troubleshooting Fusionwiki pages of interest Current shot information Obtaining data from past shots
  • Past session logs: go to Fusionwiki, then to the "Results and Analysis" section, then to the "Session Logs" subsection, then to "SL", and then pick date
    • Click on the shot number to open a pdf which has a collection of waveforms from plasma and toroidal field currents to the neutron rate
  • Quick Search for Shot Data: go to Fusionwiki, then to the "Results and Analysis" section, then to the "Displays" subsection, then to "Data"
    • Enter the shot number and select relevant data to view
  • XPAD
    • Documentation: within the CCFE network go to http://fusweb2.fusion.culham.ukaea.org.uk/ then to "Richard Martin" and then to "XPAD"
    • If logged into a server on the newtork type in "xpad"
    • Fission chamber data
      • go to NEUTRONICS then ANU_NEUTRONS
    • Mirnov coil data
      • go to MAGNETICS, INSTABILITY MEASUREMENTS, then OUTER MIRNOV VERTICAL (example: XMC_OMV210)
      • also view this data by running the specview command on a server in the network
    • Neutral beam power data
      • go to MACHINE MONITORING, NEUTRAL BEAM (example: ANB_SS_SUM_POWER, ANB_SW_SUM_POWER)
  • Neutron camera data
    • If logged into a server on the network go to Marco Cecconello's folder called "mcecc", then the "ProcessedData" folder, then to the appropriate shot directory
    • use 'eog' or 'okular' or some other command to view the .png files

CCFE Useful Travel Information

Transportation from Abingdon town centre to the lab

  • Thames Travel bus 114 or 116 (several in the morning)
  • Taxi (should not cost more than 10 pounds until late evening)
  • Long way: take the X3, X13, or 35 bus to Oxford and then take the train from OXF to CUM (check train times)
Transportation from the lab to Abingdon town centre
  • Thames Travel bus 114 or 116 (last one leaves before 6:30PM)
  • Taxi (should not cost more than 10 pounds until late evening)
  • Train from CUM to RAD then 35 bus to Abingdon
Staying at the lab past normal working hours?
  • Transportation
    • Take the train from OXF to RAD, walk 1 minute to the bus station around the corner, then take the 35 bus to Abingdon town centre
      • Always check train times!
      • It is not common for a ticket collector to be present to charge for tickets on the evening trains (past 8PM) from CUM to RAD
    • If you plan on taking a taxi to leave the lab late, remember that they take cash
      • If you are out of cash go to the ATM near the canteen before you leave and before they lock the doors to enter the area
      • You can call to schedule a taxi pickup outside of the visitor center/ entrance to the CCFE several hours in advance
  • Food
    • The Railway Inn, next to the train station, serves dinner until around 8:30PM (check the official times online)
    • There is a vending machine on the bottom floor of D3
    • There are coffee/ hot chocolate/ hot water vending machines in break rooms
  • Lights and Security
    • Most lights are turned off after normal working hours
      • If you have trouble finding light switches in the pitch black when you need to get to a restroom, lab, or office, the lights on the bottom floor of D3 are connected to motion sensors
    • Note that if you leave to get food and return to the lab, it is possible that they might have locked up the building to which you need access
      • If this is the case then security will have to open the building for you, you can check at the gate to see if the building has been locked up or not during your absence
    • Many times the security guards will stop by your lab or office to find out what time you plan on leaving so they can plan accordingly
    • Weekend work
      • You should coordinate with your CCFE colleagues to get approval for weekend work beforehand
      • When you arrive at the lab you need to tell the security guard which building you plan on working in and approximately how late you plan on working

Funding Acknowledgements

  • This material is based upon work supported by the U.S. Department of Energy under Award Number DE-SC0001157, Florida International University, and the Ronald E. McNair Post- Baccalaureate Achievement Program.

Back to FEPP

-- RamonaValenzuelaPerez - 2013-09-25

Edit | Attach | Watch | Print version | History: r92 | r70 < r69 < r68 < r67 | Backlinks | Raw View | Raw edit | More topic actions...
Topic revision: r68 - 2014-01-09 - lc_2eramona
 
  • Edit
  • Attach
This site is powered by the TWiki collaboration platform Powered by PerlCopyright © 1999-2024 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding TWiki? Send feedback
Note: Please contribute updates to this topic on TWiki.org at TWiki:TWiki.MAST_Diagnostic.